Goldshine load cell
Load cell |  Weighing Scale |  Weighing Accessories
Compression Load Cell CY Self-restoring rocker-pin module
Compression Load Cell CY
Compression Load Cell CY

Model

CY

Rated load

10,20,30,40,50,60t

Description

The load cell /sensor can use in truck scale, railway scale, axle wheel scale, floor scale. Double cambered surface column structure, high precision, high reliability and dexterity.CY applies the elastic multiple board, it improves its overload while compared with the usual column sensor. Sealed three times.

Accuracy class

C2/C3

 

 

Sensitivity

2±0.1%mV/V

Load type

press load cell

Protection

IP67/68

Temperature

-30~70℃

Optional

The load cell can be produced into analog load cell, digital load cell, wireless load cell.
The material: alloy steel, stainless steel  

Use range

 

Packaging

(carton)

Rated load

10~30t

40~60t

Net.(kg)/CTN

5.9kg/4pcs/CTN

8.3kg/2pcs/CTN

Measurement/Weight:37×22×27mm / 0.7kgs



Compression Load Cell CY

Compression Load Cell CY

Description

Capacities (Emax)
10,20,30,40,50,60t.

Output:
Analog: 2.0mV /V.
Digital: 30, 000 or 100,000d.

Accuracy
3000d OIML R60.

Material of load cell block:
Alloy steel o r stainless steel.

Approvals
OIML R60 C erti fica te
Accuracy class C3.
Vmin= Em ax/15000

Sealed to IEC 529.

Classification IP67 or IP68.Protection against total immersion in water for 30 minutes at a
pressure corresponding to a 1 m head of water.

Dimensions
(In mm . 1mm = 0.03937 inches)

Compression Load Cell CY

Model: CY Specification

Item\ Parameter C2 C3 UNIT
Rated load (Emax): 10,20,25,30,40,50,60 t
Maximal numbers of load cell verification Intervals(Nlc): 2000 3000 d
Minimum load cell verification intervals(Vmin) 0.02 0.01 % of rated l oad
Sensitivity(Cn): 2.0 ± 0.1% mV/V
*Combined error: 0.027 0.015 ±% o f rated output
Temperature effect on sensitivity (Tkc): 0.0024 0.0012 ±% of rated output/
Temperature effect on zero balance (Tk0): 0.002 0.0008 ±% o f rated output/
Zero balance: 1.0 ⊥±% o f rated output
Input resistance(Rlc): 775±5 Ω(O hms )
Output resistance(R0): 701±2 Ω(O hms )
Insulation resistance: ≥5000 MΩ(M ega-Ohms)
Safe overload: 150 % of rated c apability
Ultimate overload: 300 % of rated c apability
Operating temperature range: -30~+ 70/-20~+ 160 ℃/ ℉
Recommend excitation: 12 V (AC or DC)
Maximum excitation: 24 V (AC or DC)
Material of elastomer: alloy steel / stainless steel
Protection class: IP67/IP68
Citation: OIML R60 / GB7551-1997
The data for deviation of synthesis error, TKo, TKc are typicl values. The sum of these data meets the requirements according to OIML R60.


Compression Load Cell CY

Circuit Diagram

Electrical Termination
4 Core cable standard lengths: 12.0 m.
Excitation: black -Ve, red +Ve
Signal: white -Ve, green +Ve
Screen: yellow
Diameter: Ф6

Note:
Do not change length of 4
core cables, or else it will
effect sensitivity of load cell.



Copyright©,Ningbo G-Shine Electronic Co., Ltd. All Rights Reserved   link | Site Map | Load Cells | weighing scale