You are here : Home > Products > Load Cell > Tension Load Cell > BH


Model |
BH |
Rated load |
1,2,3,5,10,20,30,40,50,60t |
|
Description |
The load cell can be used in the Hook scale, Hopper scale, Packing scale, overload limiter, crane scale. Multiple-board & circle structure. Has high precision than usual sensor, super in overload. |
|||
Accuracy class |
C2/C3 |
|
|
|
Sensitivity |
2±0.1%mV/V |
Load type |
pull |
|
Protection |
IP67/68 |
Temperature |
-30~70℃ |
|
Optional |
The load cell can be produced into analog load cell, digital load cell, wireless load cell. |
|||
Use range |
Can be used to the rebuild of crane sinker wheel machine at the port and some simple equipment inspection. the Hook scale, Hopper scale, Packing scale, overload limiter, crane scale. |
|||
Packaging
(carton) |
Rated load |
1~5t |
7.5~10t |
|
Net.(kg)/CTN |
2.9kg/4pcs/CTN |
7.5kg/4pcs/CTN |
||
Measurement/Weight:0.41×0.21×0.21 m / 0.7kg |
||||
Remarks |
/ |
|||

![]()
Capacities (Emax)
1,2,3,5,7. 5,10,20,30,40,50,60t
Output:
Analog: 2.0mV /V.
Digital: 30,000 or 100,000d.
Accuracy
3000d OIML R60.
Material of load cell block:
Alloy steel o r stainless steel.
Approvals
OIML R60 C erti fica te
Accuracy class C3.
Vmin= Em ax/15000
Sealed to IEC 529.
Classification IP67 or IP68.Protection against total immersion in water for 30 minutes at a pressure
corresponding to a 1m head of water.

| Item\ Parameter | C2 | C3 | UNIT |
| Rated load (Emax): | 1,2,3,5,7.5, 10,2,30,40, 50,60 | t | |
| Maximal numbers of load cell verification Intervals(Nlc): | 2000 | 3000 | d |
| Minimum load cell verification intervals(Vmin) | 0.02 | 0.01 | % of rated l oad |
| Sensitivity(Cn): | 2.0 +/-0.1% | mV/V | |
| *Combined error: | 0.027 | 0.015 | +% o f rated output |
| Temperature effect on sensitivity (Tkc): | 0.0024 | 0.0012 | ⊥% of rated output/ |
| Temperature effect on zero balance (Tk0): | 0.002 | 0.0008 | +% o f rated output/ |
| Zero balance: | 1.0 | ⊥% o f rated output | |
| Input resistance(Rlc): | 385 ? | Ω(O hms ) | |
| Output resistance(R0): | 351 ? | Ω(O hms ) | |
| Insulation resistance: | ≥5000 | MΩ(M ega-Ohms) | |
| Safe overload: | 150 | % of rated c apability | |
| Ultimate overload: | 300 | % of rated c apability | |
| Operating temperature range: | -30~+ 70/-20~+ 160 | ℃/ ℉ | |
| Recommend excitation: | 9 | V (AC or DC) | |
| Maximum excitation: | 18 | V (AC or DC) | |
| Material of elastomer: | alloy steel / stainless steel | ||
| Protection class: | IP67/IP68 | ||
| Citation: | OIML R60 / GB7551-1997 | ||

Electrical Termination
1~3t:3m. >=7.5:6m.
Excitation: black -Ve, red +Ve
Signal: white -Ve, green +Ve
Screen: yellow
Diameter: Ф6
Note:
Do not change length of 4
core cables, or else it will
effect sensitivity of load cell.