Goldshine load cell
Load cell |  Weighing Scale |  Weighing Accessories

You are here : Home > Products > Load Cell > Tension Load Cell > GLA

Tension Load Cell GLA Special for crane scale

Tension Load Cell GLA

Tension Load Cell GLA


Model

GLA

Rated load

0.5,1,2,3,5,10,20t,30t

Description

The design is all-in-one, high precision, easy installation, super load. Can be used with international standard hook and flying rings.

Accuracy class

C2/C3

Changeable

usual,high tempe,digital

Sensitivity

2±0.1%mV/V

Load type

pull

Protection

IP67/68

Temperature

-30~70ºC

Use range

Can be used in crane scale.

Packaging

(carton)

Rated load

1~5t

7.5~10t

15~20t

Net.(kg)/ctn

2.8kg/4pcs/ctn

3.9kg/4pcs/ctn

9.2kg/2pcs/ctn

 



Tension Load Cell GLA

Tension Load Cell GLA

Description

Capacities (Emax)
1 ,2, 3,5 ,7. 5, 10 ,20t ,30t

Output:
Analog: 2.0mV /V.
Digital: 30,000 or 100,000d.

Accuracy
3000d OIML R60.

Material of load cell block:
Alloy steel o r stainless steel.

Approvals
OIML R60 C erti fica te
Accuracy class C3.
Vmin= Em ax/15000

Sealed to IEC 529.
Classification IP67 or IP68.Protection against total immersion in water for 30 minutes at a pressure corresponding to a 1m head of water.

Dimensions
(In mm . 1mm = 0.03937 inches)

Tension Load Cell GLA


Model: GLA Specification

Item\ Parameter C2 C3 UNIT
Rated load (Emax): 1,2,3,5,7.5, 10,2,30,40, 50,60 t
Maximal numbers of load cell verification Intervals(Nlc): 2000 3000 d
Minimum load cell verification intervals(Vmin) 0.02 0.01 % of rated l oad
Sensitivity(Cn): 2±0.1% mV/V
*Combined error: 0.027 0.015 ±% o f rated output
Temperature effect on sensitivity (Tkc): 0.0024 0.0012 ±% of rated output/
Temperature effect on zero balance (Tk0): 0.002 0.0008 ±% o f rated output/
Zero balance: 1.0 ±% o f rated output
Input resistance(Rlc): 385 ±5 Ω(O hms )
Output resistance(R0): 351 ±2 Ω(O hms )
Insulation resistance: ≥5000 MΩ(M ega-Ohms)
Safe overload: 150 % of rated c apability
Ultimate overload: 300 % of rated c apability
Operating temperature range: -30~+ 70/-20~+ 160 ℃/ ℉
Recommend excitation: 9 V (AC or DC)
Maximum excitation: 18 V (AC or DC)
Material of elastomer: alloy steel / stainless steel
Protection class: IP67/IP68
Cable Ф6       13m (10~30t) / 18m (40~60t)
Citation: OIML R60 / GB7551-1997
The data for deviation of sythesis error, Tko,Tkc are typicl values. The sum of these data meets the requirements according to OIML R60.


Tension Load Cell GLA

Circuit Diagram

Electrical Termination
1~3t:3m. >=7.5:6m.
Excitation: black -Ve, red +Ve
Signal: white -Ve, green +Ve
Screen: yellow
Diameter: Ф6

Note:
Do not change length of 4
core cables, or else it will
effect sensitivity of load cell.


Copyright©,Ningbo G-Shine Electronic Co., Ltd. All Rights Reserved   link | Site Map | Load Cells | weighing scale