You are here : Home > Products > Load Cell > Tension Load Cell > GLD

Model |
GLD |
Rated load |
1.5,3,5,7.5,10,12.5 |
|
Description |
The load cell can be used in the Hook scale, Hopper scale, Packing scale, overload limiter, crane scale. The design is all-in-one, high precision, easy installation, super load. Can be used with international standard hook and flying rings. |
|||
Accuracy class |
C2/C3 |
|
|
|
Sensitivity |
2±0.2%mV/V |
Load type |
pull |
|
Protection |
IP67/68 |
Temperature |
-30~70℃ |
|
Optional |
The load cell can be produced into analog load cell, digital load cell, wireless load cell. |
|||
Use range |
Can be used in The load cell can be used in the Hook scale, Hopper scale, Packing scale, overload limiter, crane scale. |
|||
Packaging
(carton) |
Rated load |
|||
Net.(kg)/CTN |
||||
Measurement/Weight: |
||||

Technical data | (Unit) | Technical quota |
Rated Load | t | 1.5,3,5,7.5,10,12.5 |
Sensitivity | mV/V | 2.0±0.002 |
Total error | %F.S | ±0.03 |
Creep(30mins) | %F.S | ±0.02 |
Zero balance | %F.S | ±1 |
TCO | %F.S/10℃ | ±0.02 |
TC SPAN | %F.S/10℃ | ±0.02 |
Input resistance | Ω | 380±10 |
Output resistance | Ω | 352±2 |
Insulation resistance | Ω | ≥5000M |
Operating Temp Range | ℃ | -30~+70 |
Safe load limit | %F.S | 120 |
Lateral load limit | %F.S | 150 |
Recommend excitation | V DC | 10~12 |
Max. excitation | V DC | 15 |
Protection Class |
IP68 |
|
Material |
Alloy Steel / stainless steel |
|
Cable |
Diameterφ6;Length:1m |
|