You are here : Home > Products > Load Cell > Tension Load Cell > PST-B

Model |
PST-B |
Rated load |
5, 7.5t |
||
Description |
The load cell can be used in hoop scale, blending scale, packing scale, mechanism and electronical combined scale, special testing device. |
||||
Accuracy class |
C2/C3 |
Changeable |
usual,stainless steel |
||
Sensitivity |
2±0.2%mV/V |
Load type |
pull/press |
||
Protection |
IP66/67 |
Temperature |
-30~70℃ |
||
Optional |
The load cell can be produced into analog load cell, digital load cell, wireless load cell. |
||||
Use range |
Can be used in combination scale, package scale, systematic scale and belt scale, hoop scale, blending scale, packing scale, mechanism and electronical combined scale, special testing device. |
||||
| Packaging (carton) |
Rated load |
|
|
|
|
Net.(kg)/CTN |
|
|
|
|
|
Measurement/Weight:0.41×0.21×0.21 m/ 0.7kg |
|||||

Main Technical data |
(Unit) |
Technical quota |
Rated Load |
t |
5,7.5 |
Sensitivity |
mV/V |
2.0±0.002 |
Total error |
%F.S |
±0.03 |
Creep(30mins) |
%F.S |
±0.02 |
Zero balance |
%F.S |
±1 |
TCO |
%F.S/10℃ |
±0.02 |
TC SPAN |
%F.S/10℃ |
±0.02 |
Input resistance |
Ω |
380±10 |
Output resistance |
Ω |
353±2 |
Insulation resistance |
Ω |
≥5000M |
Operating Temp Range |
℃ |
-30~+70 |
Safe load limit |
%F.S |
120 |
Lateral load limit |
%F.S |
150 |
Recommend excitation |
V DC |
10~12 |
Maximum excitation |
V DC |
15 |
Protection Class |
IP67/IP68 |
|
Material |
Alloy Steel/Stainless steel |
|
Cable |
Dimeter:φ6;Length:3m |
|